Air Dryer
HKP Series air dryers are designed with the principle of “Maximum Performance in Difficult Conditions” and operate up to 140 °F inlet and 122 °F ambient temperatures, thanks to the environmentally friendly R134a gas and large surface area condensers.
Integrated Filters
The inlet and outlet filters placed in the canopy not only increase the performance and quality, but also prevent the extra piping required to the inlet and outlet of the dryer.
Compact Design
Every centimeter inside the dryer has been used with care and high efficiency.
Easy Access
With screwless connections and plastic handles, it takes a few seconds to reach the cooling circuit.
Internal Ventilation
With the ventilation duct placed in the interior of the dryers whose condensers are placed on the upper part, it is ensured that the hot air passing through the condenser is not fed back into the dryer. Thus, maximum efficiency is achieved in in-machine ventilation.
Outdoor Ventilation
Thanks to the specially designed bolts placed on the upper canopy sheet in large dryers with the condenser placed on the upper part, the external ventilation channels (to prevent the machine room from overheating or to heat other rooms with the hot air coming out) can be easily mounted and do not require extra labor.
Automatic Evacuation System
Liquid water droplets coming from the line are separated and removed by the water separator before entering the dryer, thus maximizing the performance of the dryer.
Insulation
All necessary parts are covered with insulation material of sufficient thickness in order to prevent the heat from the external environment and to ensure the highest performance. Here, not only the cooling circuit, but also the cold drainage pipes and hoses are not overlooked.
Independent Electrical Panel
The panel is isolated from the cooling circuit. The panel with the outer cover provides quick access during any electrical operation without the need to open the dryer canopies.
Dryer Electrical Connection
It is quite easy to make an electrical connection to the dryer. The electrical line cables fixed with the unions provide direct access to the electrical box without entering the dryer.
Hot Gas By-Pass Valve
By-Pass Valve Especially in large dryers, Hot Gas By-Pass valves are also quite large. In large dryers, even a small amount of hot gas sent unintentionally affects the dryer performance badly. For this reason, we take care not to use ordinary Hot Gas By-Pass valves in large systems we design. While the valve used is controlled by pressure as in ordinary HGBPVs, it also maximizes performance by closing the solenoid valve fully when the dryer requires 100% cooling.
Low Pressure Refrigirated Air Dryers
|
Number
|
Name
|
Capacity
|
Connection
|
Pressure
|
Filter
|
Price
|
|---|---|---|---|---|---|---|
|
1
|
Max-900
|
32 cfm
|
1/2″
|
235 PSI
|
Included
|
|
|
2
|
Max-1200
|
42 cfm
|
1/2″
|
235 PSI
|
Included
|
|
|
3
|
Max-1800
|
64 cfm
|
3/4″
|
235 PSI
|
Included
|
|
|
4
|
Max-2200
|
78 cfm
|
3/4″
|
235 PSI
|
Included
|
|
|
5
|
Max-2600
|
92 cfm
|
1″
|
235 PSI
|
Included
|
|
|
6
|
Max-3100
|
110 cfm
|
1″
|
235 PSI
|
Included
|
|
|
7
|
Max-3700
|
131 cfm
|
1″
|
235 PSI
|
Included
|
|
|
8
|
Max-4500
|
159 cfm
|
1″
|
235 PSI
|
Included
|
|
|
9
|
Max-5500
|
194 cfm
|
1″
|
235 PSI
|
Included
|
|
|
10
|
Max-6500
|
229 cfm
|
1.5″
|
235 PSI
|
Included
|
|
|
11
|
Max-8500
|
300 cfm
|
1.5″
|
235 PSI
|
Included
|
|
|
12
|
Max-11000
|
388 cfm
|
2″
|
235 PSI
|
Included
|
|
|
13
|
Max-13000
|
459 cfm
|
2″
|
235 PSI
|
Included
|
|
|
14
|
Max-17000
|
600 cfm
|
2″
|
235 PSI
|
Included
|
|
|
15
|
Max-20000
|
706 cfm
|
2″
|
235 PSI
|
Included
|
|
|
16
|
Max-25000
|
883 cfm
|
2″
|
235 PSI
|
Included
|
|
|
17
|
Max-30000
|
1059 cfm
|
3″
|
235 PSI
|
Included
|
|
|
18
|
Max-35000
|
1236 cfm
|
3″
|
235 PSI
|
Included
|
|
|
19
|
Max-40000
|
1413 cfm
|
3″
|
235 PSI
|
Included
|
|
|
20
|
Max-45000
|
1589 cfm
|
3″
|
235 PSI
|
Included
|
|
|
21
|
Max-50000
|
1766 cfm
|
3″
|
235 PSI
|
Included
|
|
|
22
|
Max-60000
|
2119 cfm
|
DN100
|
235 PSI
|
Not Included
|
|
|
23
|
Max-70000
|
2472 cfm
|
DN100
|
235 PSI
|
Not Included
|
|
|
24
|
Max-80000
|
2825 cfm
|
DN100
|
235 PSI
|
Not Included
|
|
|
25
|
Max-90000
|
3178 cfm
|
DN100
|
235 PSI
|
Not Included
|
|
|
26
|
Max-105000
|
3708 cfm
|
DN150
|
235 PSI
|
Not Included
|
|
|
27
|
Max-120000
|
4238 cfm
|
DN150
|
235 PSI
|
Not Included
|
|
|
28
|
Max-140000
|
4944 cfm
|
DN150
|
235 PSI
|
Not Included
|
|
|
29
|
Max-160000
|
5650 cfm
|
DN200
|
235 PSI
|
Not Included
|
High Pressure Refrigirated Air Dryers
|
Number
|
Name
|
Capacity
|
Connection
|
Pressure
|
Filter
|
Price
|
|---|---|---|---|---|---|---|
|
1
|
MAXHP-900
|
32 cfm
|
1/2″
|
600 PSI
|
Not Included
|
|
|
2
|
MAXHP-1200
|
42 cfm
|
1/2″
|
600 PSI
|
Not Included
|
|
|
3
|
MAXHP-1800
|
64 cfm
|
3/4″
|
600 PSI
|
Not Included
|
|
|
4
|
MAXHP-2200
|
78 cfm
|
3/4″
|
600 PSI
|
Not Included
|
|
|
5
|
MAXHP-2600
|
92 cfm
|
1″
|
600 PSI
|
Not Included
|
|
|
6
|
MAXHP-3100
|
110 cfm
|
1″
|
600 PSI
|
Not Included
|
|
|
7
|
MAXHP-3700
|
131 cfm
|
1″
|
600 PSI
|
Not Included
|
|
|
8
|
MAXHP-4500
|
159 cfm
|
1″
|
600 PSI
|
Not Included
|
|
|
9
|
MAXHP-5500
|
194 cfm
|
1″
|
600 PSI
|
Not Included
|
|
|
10
|
MAXHP-6500
|
229 cfm
|
1.5″
|
600 PSI
|
Not Included
|
|
|
11
|
MAXHP-8500
|
300 cfm
|
1.5″
|
600 PSI
|
Not Included
|
|
|
12
|
MAXHP-11000
|
388 cfm
|
2″
|
600 PSI
|
Not Included
|
|
|
13
|
MAXHP-13000
|
459 cfm
|
2″
|
600 PSI
|
Not Included
|
|
|
14
|
MAXHP-17000
|
600 cfm
|
2″
|
600 PSI
|
Not Included
|
|
|
15
|
MAXHP-20000
|
706 cfm
|
2″
|
600 PSI
|
Not Included
|
|
|
16
|
MAXHP-25000
|
883 cfm
|
2″
|
600 PSI
|
Not Included
|
|
|
17
|
MAXHP-30000
|
1059 cfm
|
3″
|
600 PSI
|
Not Included
|
|
|
18
|
MAXHP-35000
|
1236 cfm
|
3″
|
600 PSI
|
Not Included
|
|
|
19
|
MAXHP-40000
|
1413 cfm
|
3″
|
600 PSI
|
Not Included
|
|
|
20
|
MAXHP-45000
|
1589 cfm
|
3″
|
600 PSI
|
Not Included
|
|
|
21
|
MAXHP-50000
|
1766 cfm
|
3″
|
600 PSI
|
Not Included
|